Skip to main content

Table 1 SomaticSeq sensitivity on real data. ≥N tools represents the consensus of at least N callers. The two sets of real tumor–normal sequencing data were downloaded from the European Genome Archive. SomaticSeq predictions were trained from the DREAM Stage 3 data sets

From: An ensemble approach to accurately detect somatic mutations using SomaticSeq

Sample

COLO-829

CLL1

SNV

Number of calls

Sensitivity

Number of calls

Sensitivity

MuTect

46,831

0.996

8,361

0.895

VarScan2

64,927

0.987

19,797

0.888

SomaticSniper

53,077

0.996

13,690

0.907

JointSNVMix2

85,983

0.996

22,534

0.899

VarDict

53,076

0.857

5,748

0.883

Union of five tools

191,696

0.998

55,196

0.935

≥2 tools

57,254

0.996

13,594

0.916

≥3 tools

43,848

0.996

5,836

0.904

≥4 tools

38,216

0.996

2,637

0.886

=5 tools

34,086

0.857

1,749

0.842

SomaticSeq

37,452

0.996

2,320

0.892